Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
BMC Musculoskelet Disord ; 25(1): 194, 2024 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-38439044

RESUMO

BACKGROUND: In total hip arthroplasty (THA) after failed transtrochanteric rotational osteotomy (TRO) for osteonecrosis of the femoral head (ONFH), deformity of the proximal femur has been reported to affect stem placement. The aims of this study were to evaluate the morphological changes in the proximal femur, muscle atrophy, and soft tissue thickening in THA after TRO and the clinical outcomes. METHODS: The TRO group included 17 patients (18 hips) who underwent THA after failed TRO. The control group included 21 patients (28 hips) who underwent primary THA for ONFH. To evaluate the deformity of the proximal femur before THA, we measured the anteroposterior and mediolateral diameters of the femur on computed tomographic slices 5 mm proximal to the lesser trochanter. To evaluate muscle atrophy and soft tissue thickening, we measured the thicknesses of the psoas major, iliac, and gluteus medius muscles and the anterior capsule of the hip joint. RESULTS: The ratio of the anteroposterior to mediolateral diameters of the proximal femur was significantly greater in the TRO group (p < 0.01). The thicknesses of the muscles did not differ between the two groups, whereas the anterior capsule was significantly thicker in the TRO group (p < 0.05). Varus or valgus stem alignment (> 3°) was frequent in the TRO group (p < 0.01). CONCLUSIONS: The round shape of the proximal femur was deformed after TRO compared with primary THA for ONFH, which may have caused malposition of the stem. In addition, we should pay attention to anterior protrusion of the proximal femur and thickening of the anterior capsule.


Assuntos
Artroplastia de Quadril , Osteonecrose , Humanos , Artroplastia de Quadril/efeitos adversos , Cabeça do Fêmur , Atrofia Muscular , Osteotomia
2.
BMJ Case Rep ; 16(4)2023 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-37011998

RESUMO

Secure fixation by inserting a half-pin into the iliac crest as a pelvic external fixator is important. However, the thickness of the iliac bone depends on its location and this makes it difficult to insert a half-pin accurately. The iliac crest is especially narrow in the paediatric pelvis, making it difficult to insert the half-pin accurately compared with an adult pelvis. A case of pelvic external fixation is described for a paediatric pelvic fracture in this report, in which preoperative planning for half-pin insertion was performed accurately using a preoperative three-dimensional CT based on an intraoperative support device that uses the functional pelvic plane as a reference.


Assuntos
Fraturas Ósseas , Ossos Pélvicos , Adulto , Humanos , Criança , Fixadores Externos , Fixação de Fratura/métodos , Pinos Ortopédicos , Ossos Pélvicos/diagnóstico por imagem , Ossos Pélvicos/cirurgia , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/cirurgia
3.
J Orthop Sci ; 28(5): 1034-1040, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35995684

RESUMO

BACKGROUND: Curved periacetabular osteotomy (CPO) is indicated for patients with developmental dysplasia of hip (DDH) to prevent progressive osteoarthritis. Patients with DDH have not only lateral acetabulum dysplasia but also anterior and posterior dysplasia. The full circumference acetabular coverage angle (ACA) of the femoral head should be evaluated preoperatively. This study aimed to determine the full circumference ACA in the patients with DDH before and after CPO compared with the coverage in normal patients. METHODS: Twenty-three patients (a total of 24 hips) with DDH undergoing CPO between February 2006 and March 2014 were included in this study. The normal group was defined as the normal side in patients with unilateral osteonecrosis of the femoral head (ONFH) and the non-collapsed femoral head side in patients with bilateral ONFH. Pre- and postoperative hip functions were evaluated using the Japanese Orthopedic Association (JOA) hip score. ACA was measured using pre- and postoperative three-dimensional computed tomography (3DCT) and described as a clock using a radar chart. The ACA of the normal group was evaluated in the same manner as that for patients who underwent CPO. The ACA before CPO was compared with the ACA after CPO, the ACA before CPO was compared with that of the normal group and the ACA after CPO was compared with that of the normal group at each location. RESULTS: The mean JOA hip scores improved significantly from 69 preoperatively to 88 postoperatively. The superior, posterior, and anterior ACA after CPO significantly increased and the inferior ACA decreased compared with ACA before CPO. The superior, posterior, and anterior ACA before CPO were significantly smaller than ACA in the normal group. The ACA after CPO were similar to the normal group. CONCLUSIONS: CPO improved the anterosuperior coverage of the femoral head but reduced its inferior coverage. The radar chart could visualize acetabulum full circumference and was useful for three-dimensional pre-postoperative evaluation.


Assuntos
Acetábulo , Luxação Congênita de Quadril , Humanos , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Radar , Articulação do Quadril/cirurgia , Luxação Congênita de Quadril/diagnóstico por imagem , Luxação Congênita de Quadril/cirurgia , Osteotomia/métodos , Estudos Retrospectivos
4.
J Orthop Sci ; 2022 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-36369221

RESUMO

BACKGROUND: Heterotopic ossification of large joints, such as knees and hips, has been reported after spinal cord injury, possibly leading to decreased activity of daily living due to a limited range of motion of the affected joint. Therefore, heterotopic ossification resection is performed to improve the range of motion, but it might cause massive bleeding as a complication. METHODS: In this case, the patient had a history of spinal cord injury and developed heterotopic ossification after the left hip injury. He had left hip ankylosis and could not transfer to a wheelchair by himself; therefore, heterotopic ossification resection was planned. On conducting contrast-enhanced computed tomography, the supplying arteries extending to the heterotopic ossification could be identified. A day before the surgery, embolization of the branches by interventional radiology was performed. RESULTS: Heterotopic ossification resection was performed with an 820-ml blood loss. Postoperative rehabilitation was continued, and range of motion continued to improve without heterotopic ossification recurrence 2 years post-surgery. CONCLUSIONS: The combination of preoperative contrast-enhanced computed tomography and embolization was useful in treating heterotopic ossification.

5.
Arthroplast Today ; 16: 46-52, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35647246

RESUMO

Background: Accurate cup placement during total hip arthroplasty (THA) is difficult because the intraoperative pelvic position changes even in supine patient position. We developed a device known as HipPointer; it corrects pelvic rotation and creates a functional pelvic plane as a reference. The aim of this study was to determine the device placement accuracy and investigate causes of error. Material and methods: HipPointer was used for cup placement in 353 hips of 308 patients who underwent direct-anterior-approach THA in supine position. The mean age at surgery and body mass index were 63.9 (17-90) years and 24.9 (16.6-42.0) kg/m2, respectively. The mean observation period was 40.5 (12-73) months. To investigate the accuracy of HipPointer, preoperative planning and postoperative cup placement angles relative to the functional pelvic plane were evaluated using a three-dimensional analysis software, and absolute errors were determined. Results: The means ± standard deviations of radiographic inclination (RI) and radiographic anteversion (RA) were 40.2 ± 3.0° and 15.8 ± 3.6°, respectively. The absolute errors of RI and RA were 2.2 ± 2.0° and 2.7 ± 2.3°, respectively. The ratio of the cup placement angle for which both RI and RA are ≤10° in the target zone was 99% (350/353 hips), and the ratio of the absolute errors for which both RI and RA are ≤5° was 80.4% (284/353 hips). Conclusions: HipPointer is simple in structure, easy to use, and useful for direct-anterior-approach THA in supine position. It provides good cup placement accuracy.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...